Details

Windows Server HP 服务器磁盘阵列检测

2021/7/18 20:19:31

机器环境 系统版本:Windows Server2012 硬件型号:HP ProLiant DL380 G6

HP ProLiant Array Configuration Utility (CLI)信息查看

1.下载安装

https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_33fe6fcf4fcb4beab8fee4d2dc

打不开自己想办法科学访问

2.使用帮助 安装之后进入阵列配置界面hpacucli

image-20210510150925685

查看阵列卡与硬盘状态信息

` => => ctrl all show status #查看阵列卡槽位

Smart Array P410i in Slot 0 (Embedded) Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK

=> ctrl slot=0 show config detail #查看阵列卡信息

Smart Array P410i in Slot 0 (Embedded) #阵列卡信息 Bus Interface: PCI Slot: 0 Serial Number: 50123456789ABCDE Cache Serial Number: PAAVP9SYH77X RAID 6 (ADG) Status: Disabled Controller Status: OK 略…………

Array: A #阵列A信息 Interface Type: SAS Unused Space: 0 MB Status: OK 略………… Array: B #阵列B信息 Interface Type: SAS Unused Space: 0 MB Status: OK 略………… unassigned #未配置硬盘 略…………

=> controller slot=0 logicaldrive all show #查看当前RAID

Smart Array P410i in Slot 0 (Embedded)

array A

  logicaldrive 1 (136.7 GB, RAID 1, OK)

array B

  logicaldrive 2 (410.1 GB, RAID 1+0, OK)

=> ctrl slot=0 pd all show status #查看硬盘健康状态

physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 146 GB): OK physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 146 GB): OK physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 146 GB): OK physicaldrive 1I:1:4 (port 1I:box 1:bay 4, 146 GB): OK physicaldrive 2I:1:5 (port 2I:box 1:bay 5, 146 GB): OK physicaldrive 2I:1:6 (port 2I:box 1:bay 6, 146 GB): OK physicaldrive 2I:1:7 (port 2I:box 1:bay 7, 146 GB): Predictive Failure #这块盘故障 physicaldrive 2I:1:8 (port 2I:box 1:bay 8, 146 GB): OK `

3.收集故障硬盘报告

` => ctrl all diag file=/home/HPDL380G6.zip

Generating diagnostic report...done

done

=> exit `

参考:

HP服务器硬件检测